QM48T45 Family DC-DC Converter Data Sheet
36-75 VDC Input; 1.0-3.3 VDC @ 45 A Output
V IN
Startup Information (using negative ON/OFF)
Scenario #1: Initial Startup From Bulk Supply
ON/OFF function enabled, converter started via application
of V IN . See Figure F.
Time Comments
ON/OFF
STATE
OFF
t 0
t 1
t 2
ON/OFF pin is ON; system front end power is
toggled on, V IN to converter begins to rise.
V IN crosses Undervoltage Lockout protection
circuit threshold; converter enabled.
Converter begins to respond to turn-on
command (converter turn-on delay).
V OUT
ON
t 3 Converter V OUT reaches 100% of nominal value.
For this example, the total converter startup time (t 3 - t 1 ) is
typically 4 ms.
t 0
t 1 t 2
t 3
t
Fig. F: Startup scenario #1.
Scenario #2: Initial Startup Using ON/OFF Pin
With V IN previously powered, converter started via
ON/OFF pin. See Figure G.
Time Comments
t 0 V INPUT at nominal value.
t 1 Arbitrary time when ON/OFF pin is enabled
(converter enabled).
t 2 End of converter turn-on delay.
t 3 Converter V OUT reaches 100% of nominal value.
For this example, the total converter startup time (t 3 - t 1 ) is
typically 4 ms.
Scenario #3: Turn-off and Restart Using ON/OFF Pin
With V IN previously powered, converter is disabled and
then enabled via ON/OFF pin. See Figure H.
V IN
ON/OFF
STATE OFF
ON
V OUT
Time Comments
t 0 V IN and V OUT are at nominal values; ON/OFF pin
ON.
t 1 ON/OFF pin arbitrarily disabled; converter
output falls to zero; turn-on inhibit delay period
(100 ms typical) is initiated, and ON/OFF pin
action is internally inhibited.
t 2
ON/OFF pin is externally re-enabled.
If (t 2 - t 1 ) ≤ 100 ms , external action of
ON/OFF pin is locked out by startup inhibit
V IN
t 0 t 1 t 2 t 3
Fig. G: Startup scenario #2.
t
timer.
If (t 2 - t 1 ) > 100 ms , ON/OFF pin action is
internally enabled.
ON/OFF
STATE OFF
100 ms
t 3
Turn-on inhibit delay period ends. If ON/OFF pin
is ON, converter begins turn-on; if off, converter
awaits ON/OFF pin ON signal; see Figure G.
ON
t 4 End of converter turn-on delay.
t 5 Converter V OUT reaches 100% of nominal value.
For the condition (t 2 - t 1 ) ≤ 100 ms , the total converter
startup time (t 5 -t 2 ) is typically 104 ms. For (t 2 -t 1 ) > 100 ms ,
V OUT
startup will be typically 4 ms after release of ON/OFF pin.
t 0
t 1
t 2
t 3 t 4
t 5
t
Fig. H: Startup scenario #3.
MCD10073 Rev. 1.0
Page 6 of 36
www.power-one.com
相关PDF资料
QME48T20120-NGA0 DC/DC QUARTER BRICK 12V OUT
QME48T40050-NGA0 DC/DC QUARTER BRICK 5V OUT
QMS07DH 19" RACK FOR 3X 48V FRONT END
QXK2E106KTP CAP FILM 10UF 250VDC RADIAL
QXK2J474KTPTZH CAP FILM 0.47UF 630VDC RADIAL
QXL2E334KTPT CAP FILM 0.33UF 250VAC RADIAL
QXP2J474KRPT CAP FILM 0.47UF 630VDC RADIAL
QXT2J103KRPT CAP FILM 10000PF 630VDC RADIAL
相关代理商/技术参数
QM48T45010-NAAPG 制造商:Power-One 功能描述:DCDC,HAZMAT - Bulk
QM48T45010-NAB0G 制造商:Power-One 功能描述:DCDC,HAZMAT - Bulk
QM48T45010-NABPG 制造商:Power-One 功能描述:DCDC,HAZMAT - Bulk
QM48T45010-NAC0G 制造商:Power-One 功能描述:DCDC,HAZMAT - Bulk
QM48T45010-NACP 功能描述:DC/DC QTR BRICK 45W 1V T/H RoHS:是 类别:电源 - 板载 >> DC DC Converters 系列:* 标准包装:5 系列:*
QM48T45010-NACPG 制造商:Power-One 功能描述:DCDC,HAZMAT - Bulk
QM48T45010-NBA0G 制造商:Power-One 功能描述:DCDC,HAZMAT - Bulk
QM48T45010-NBAPG 制造商:Power-One 功能描述:DCDC,HAZMAT - Bulk